Plant rooms and boiler houses
Pumps, valves, pressure vessels and pipe joints, all of which leak eventually.
The ZARC water leak tag is a wireless IoT water leak sensor, supplied with a ZARC Gateway and the dashboard that alerts your team the moment water reaches the floor, void, pit or bund it is watching, and again when the water clears. The tag is a small sealed box with four stainless steel pins on its base. It sits on the floor where water collects first, and water bridging the pins raises the alert. It runs on its own battery, with no cable to run.
01
Most escapes of water start small: a weeping valve, a failed hose or a condensate drain that has backed up. The tag reports the first water to reach its pins, at any hour.
It reports two events: water detected, and water cleared. The dashboard times each one, so a leak that comes and goes, such as a drain that backs up only when a machine runs, shows as a pattern rather than a mystery.
One tag watches one position. Two positions, such as both sides of a plant room or the floor under a water heater and the tray beneath it, take two tags on the same dashboard.
02
Wherever water does quiet damage before anyone sees it, the tag has a job. These are the positions we are asked about most, and the list is not exhaustive.
Pumps, valves, pressure vessels and pipe joints, all of which leak eventually.
The floor or drip tray beneath the equipment most likely to fail.
Floor voids under raised floors, and the floor under air conditioning units and their condensate drains.
Water finds its way down a riser long before it shows through a ceiling below.
Leaks here damage the floors below. An alert limits the damage to one room.
The lowest point of a building, where water collects first and is seen last.
Water collecting in a bund around a tank uses up the bund's capacity. The alert says when it needs pumping out.
An escape of water in a void unit can run for weeks. An alert turns it into a same-day visit.
Leak detection on the mains supply is one of the measures the credit looks for. Whether a design earns the credit is the assessor's judgement.
Leak alerts from the floor sit on the same dashboard as the rest of the estate's water monitoring.
03
The tag goes where water collects first, pins down on the floor. Typical positions:
In the lowest corner of a plant room, cupboard or basement.
Beneath water heaters, cylinders, pumps, washing machines and air conditioning units.
In the tray under a unit, or beside a condensate drain.
Under raised floors, in ceiling voids and at the foot of risers.
Lift pits, sump chambers and service pits.
At the low point of a bund around a tank.
04
Every tag shows its live state, dry or wet, grouped by site and building. Each leak is recorded with when water arrived, when it cleared and how long it lasted, and repeated events at one tag show as a pattern. History exports for insurers, maintenance records and building files, and is held on a UK-hosted dashboard or on servers on your own site.
Alerts are pushed the moment water is detected and again when it clears. The dashboard sends them by email or SMS, and through an app where required, to the people you name, with escalation to further contacts and separate routes in and out of hours.
05
Water damage costs every sector that owns or runs a building, including:
Plant rooms, risers and water heaters, one building or a whole estate.
One view of every leak across every client site.
Floor voids and cooling plant where water and equipment meet.
Plant rooms and water systems where an escape of water disrupts care.
Buildings that stand empty through holidays.
Pumping stations, chambers and kiosks.
06
| Parameter | Specification |
|---|---|
| Detection | Water bridging the pins; wet or dry |
| Sensing | Four stainless steel pins on the base of the tag, placed at the low point |
| Positions per tag | One; a second position takes a second tag |
| Reporting | On detection and on clearing, sent as it happens |
| Timing | Time water arrived, time it cleared, duration |
| Alert delivery | Dashboard, email or SMS; app where required |
| Recipients | Named people and groups, with escalation to further contacts |
| Check-in interval | Configurable; a silent tag is flagged |
| Gateway power loss | Raises its own platform alert |
| Dashboard | Live state, event history, repeat patterns, estate statistics; configured to your requirement |
| Parameter | Specification |
|---|---|
| Data | Full event history, exportable; UK-hosted or on servers on your own site |
| Power | Internal battery, up to five years as standard; longer with additional cells |
| Radio | 433 MHz, one-way (transmit only) |
| Range | Site-dependent; confirmed by site survey |
| Mounting | On the floor, in a tray, pit or bund, pins down at the low point |
| Environment | Indoor or outdoor, enclosure specified to the location |
| Charges | No per-alert, per-user or licence charges |
| Manufacture | Made in the UK |
| Certification | UKCA marked |
07
You tell us where water would do the most damage and who needs to know, in and out of hours.
We set the check-in interval and alert routes for each position.
Each tag goes at the low point where water collects first, pins down.
We wet every tag's pins, confirm each alert reaches every recipient, and dry them to confirm the clear.
Tags are supplied as part of a complete monitoring system with the ZARC Gateway and the dashboard, sized to the job from a single site to national scale. Every deployment starts with a conversation with one of our engineers.
Talk to an engineer08
The moment water bridges the pins, the tag sends it over 433 MHz radio to a ZARC Gateway, which passes it to the dashboard and raises the alert. The tag transmits and never listens, so there is no receiver for anyone to reach or reprogramme over the air.
Each point is two parts: the sensor or input that suits the job, and the ZARC tag we build it into, which carries the sensor's readings over our own 433 MHz radio to the ZARC Gateway and the dashboard.
Damp in the air, where this tag finds water on the floor.
A tank losing water it should be holding.
A slow fall in system pressure, the other sign of a leak.
A sump or drainage pump losing its supply.
Water bridging the four pins on its base. It reports the moment water arrives and again when it clears.
At the lowest point where water collects first: a floor corner, a drip tray, a pit, a void or a bund.
No. Each tag watches the spot it sits on. A second place takes a second tag, and both report to the same dashboard.
Yes. A second alert is sent when the pins dry, and the dashboard records how long the water was there.
Detection is sent as it happens and typically reaches the dashboard within a second.
This tag is for water. For oil or fuel, tell us the liquid and we will say what can detect it.
No. It reports and alerts. It does not operate valves, so it can never shut off a supply by mistake.
No. It runs on an internal battery for up to five years as standard, longer with additional cells.
It can form part of a leak detection design. Whether a design earns the credit is the assessor's judgement.
Yes. Every tag on every site reports to the same dashboard, grouped the way you run the estate.
No. There are no per-alert, per-user or licence charges.
Looking for something else?
Most sensing needs are met by a tag we already build, configured for your equipment. If yours needs a sensor or interface we don't list, we have the engineering to build it. Tell us what you need to measure, and we will tell you how we would do it.
Discuss your requirementTell us what is happening on site, what you need to see, and the event you need to hear about. We will come back with the system that answers it.
Direct contact
Location
Venator House, Unit 9, 15-17 St Stephen's Road, Bournemouth
Dorset, BH2 6LA · VAT GB 409644484
Products contact
Direct to the team that designs and builds the range. Tell us the equipment and the event that matters.