Plant rooms and restricted rooms
Entry outside working hours is reported the moment it happens.
The ZARC PIR tag reports when a person or animal moves within its field of view. Set the hours a space should be empty, and movement inside them raises an alert in real time. It runs on its own battery and needs no wiring, so it goes into plant rooms, compounds and empty buildings where running cable for a detector is not worth it.
01
A passive infrared sensor responds to the body heat of something moving across its view. The tag reports that movement as an event, not as a continuous reading.
Schedules decide what matters. Movement in a plant room during working hours can be logged quietly, while the same movement at night alerts at once.
It gives presence and intrusion awareness. It is not a certified intruder alarm, and it does not replace one or its monitoring.
02
Wherever a space should be empty at certain times, or its use needs to be known, the tag has a job. These are the uses we are asked about most, and the list is not exhaustive.
Entry outside working hours is reported the moment it happens.
Movement inside a building that should be empty, reported between inspections.
Movement inside a compound after it is locked.
Unmanned huts where nobody should be without a scheduled visit.
Out-of-hours movement where stock is held.
Temporary buildings left empty overnight and at weekends.
Movement counts show which rooms are used, when and how often, which is useful evidence for cleaning, heating and space planning.
Confirmation that a building is empty before it is secured for the night.
03
The tag mounts where it can see the space, and it needs no wiring. Typical positions:
Covering a room, store or plant room.
Facing a door or corridor, so anyone coming in crosses its view.
In a telecoms hut, welfare unit or equipment cabin.
Where an opening alone would not show someone inside.
In yards and compounds, in an enclosure specified for the location.
Every monitored space on one dashboard.
04
Every monitored space shows its live state and a full history of movement, with the time of each event. The dashboard counts movement per hour, day and week, shows quiet periods, and flags any movement outside a space's permitted hours, per site or across an estate. History exports for security records, audits and insurers.
Alerts are pushed in real time on movement outside the hours you set, or on any movement at all. They go by email or SMS, and through an app where required, to the people you name, with escalation to further contacts.
05
Wherever an empty space should stay empty, including:
Restricted rooms and compounds, with every out-of-hours movement reported.
Unmanned sites where movement is the first sign of a problem.
Huts and compounds with nobody on site.
Cabins and stores left empty overnight.
Plant rooms, stores and empty buildings across a portfolio.
One view of out-of-hours movement across client sites.
06
| Parameter | Specification |
|---|---|
| Sensor | Passive infrared (PIR) |
| Detects | Body heat moving across the field of view |
| Reporting | Movement events, sent as they happen |
| Re-trigger interval | Set per tag, so a busy room does not report every step |
| Coverage | Specified to the space; confirmed at site survey |
| Schedules | Hours when movement is expected, set per space |
| Alert delivery | Dashboard, email or SMS; app where required |
| Recipients | Named people and groups, with escalation to further contacts |
| Check-in interval | Configurable; a silent tag is flagged |
| Gateway power loss | Raises its own platform alert |
| Dashboard | Live state, movement history and counts, out-of-hours events; configured to your requirement |
| Data | Full event history, exportable; UK-hosted or on servers on your own site |
| Power | Internal battery, up to five years depending on activity and check-in interval |
| Radio | 433 MHz, one-way (transmit only) |
| Range | Site-dependent; confirmed by site survey |
| Mounting | Wall or corner, inside a cabin or cabinet |
| Environment | Indoor or outdoor, enclosure specified to the location |
| Charges | No per-alert, per-user or licence charges |
| Manufacture | Made to order in the UK |
| Certification | CE marked |
07
You tell us which spaces matter, when they should be empty and who needs to know.
We set the schedules, re-trigger interval and alert routes for each space.
Each tag is mounted where it sees the space and the way in.
We walk every monitored space and confirm each alert reaches every recipient before handover.
Ready to get started? Every deployment begins with a site survey.
Book a site survey08
When movement is detected, the tag sends the event over 433 MHz radio to a ZARC gateway, which passes it to the dashboard, where it is checked against the space's schedule and the alert is raised. The tag transmits and never listens, so there is no receiver for anyone to reach or reprogramme over the air.
An item being lifted or moved, where this tag sees a person moving.
The door being opened, before anyone is inside.
A person raising the alert themselves.
Lights switched on in a space that should be dark.
The body heat of a person or animal moving across its field of view.
No. Glass and walls block the infrared it senses, so it is mounted with a clear view of the space.
No. It gives presence and intrusion awareness in real time. It does not replace a certified intruder alarm or its monitoring.
Yes. Schedules set when movement is expected. Movement inside those hours can be logged quietly, and movement outside them alerts at once.
No. A re-trigger interval stops it reporting every step, and alerts can be limited to hours when the space should be empty.
Animals give off body heat too, so position and coverage are set at the site survey to suit the space.
Yes, in an enclosure specified for the location.
No. It runs on an internal battery for up to five years, depending on activity and the check-in interval.
Yes. Every monitored space on every site reports to the same dashboard.
No. There are no per-alert, per-user or licence charges.
Looking for something else?
Most sensing needs are met by a tag we already build, configured for your equipment. If yours needs a sensor or interface we don't list, we have the engineering to build it. Tell us what you need to measure, and we will tell you how we would do it.
Discuss your requirementTell us what is happening on site, what you need to see, and the event you need to hear about. We will come back with the system that answers it.
Direct contact
Location
Venator House, Unit 9, 15-17 St Stephen's Road, Bournemouth
Dorset, BH2 6LA · VAT GB 409644484
Products contact
Direct to the team that designs and builds the range. Tell us the equipment and the event that matters.