Skip to content

Pulse counting monitoring tag

The ZARC pulse counting tag counts the pulses from a meter or output you already have and reports how much has been used, interval by interval. It turns a water, electricity, gas or heat meter with a pulse output, or a counter on a machine, into live data. It alerts when there is use that should not be there, and when use that should be there has stopped. It runs on its own battery and the meter stays as it is.

01

What it reports

The tag counts every pulse and reports the count for each interval and the running total, at the interval set for the site, down to every minute. A factor set per meter turns pulses into litres, cubic metres, kilowatt hours or units.

The pattern is the point. A meter read once a month gives a total. A count every few minutes shows when the use happened: through the night, at the weekend, during a shutdown.

Use when there should be none is the most valuable alert. Water running at three in the morning in a closed building is a leak or something left on. The tag reports it the same night, not at the next bill.

The reverse matters too. No pulses from a meter that should be turning means a supply has failed, a pump has stopped or a process is down.

The tag reads the meter's output and changes nothing about the meter. It is not a billing-grade meter; the meter remains the measure.

02

Applications

Most meters already have a pulse output that nobody is using. The uses below are the common ones.

Water sub-meters

Use by building, floor or tenant, shown hour by hour, with a baseline that makes waste obvious.

Gas and heat meters

Use by boiler house, building or heat network branch, from the meter's own pulse output.

Dosing and pump counts

Strokes of a dosing pump or runs of a booster, so a pump that has stopped dosing is seen.

03

Where it can go

The tag sits beside the meter or output it counts. Typical positions:

At a water meter

In the meter chamber or cupboard, on the pulse output.

At an electricity sub-meter

In the distribution cupboard, on the meter's pulse terminals.

At a gas or heat meter

Beside the meter, connected to its pulse output by a competent person.

In a plant room

On the meters serving boilers, chillers and boosters.

On a machine

At the counter or sensor output.

In a chamber or pit

Below ground, where 433 MHz still reaches the gateway.

04

In the dashboard

Every meter shows its use for each interval, its running total and a trend from the last hour to the last year. The dashboard works out use by hour, day, week and month, the overnight baseline, and sets meters and buildings side by side. Records export for energy reports, recharges and leak investigations.

Limits are set per meter: use when there should be none, no use when there should be some, and use above a limit for a period. When one is crossed the alert is raised in real time and goes by email or SMS, and through an app where required, to the people you name, with escalation to further contacts.

  • Use for every interval, in real units
  • Running total for every meter
  • Use by hour, day, week and month
  • Overnight and weekend baseline
  • Flow when there should be none
  • No flow when there should be some
  • Meters and buildings compared side by side
  • Every alert logged with the count that raised it
  • Records exported for reports and recharges
  • A tag that misses its reporting interval is flagged

05

Industries

Pulse counting tags are fitted wherever a meter is read too rarely to be useful, including:

06

Technical specification

Pulse counting monitoring tag: technical specification
ParameterSpecification
MeasurementPulses from a meter or output, counted continuously
InputVolt-free pulse output or reed switch; fitted to suit the meter
Values reportedCount for each interval and running total
ScalingFactor per meter: litres, cubic metres, kilowatt hours or units
Pulse rateSpecified to the meter
Meter changesNone; the meter and its accuracy are untouched
Reporting intervalConfigurable, down to every minute
Use alertsFlow or consumption when there should be none
No-flow alertsNo count when there should be some
Limit alertsUse above a limit for a period you set
Time-of-day rulesSeparate rules for occupied and empty hours
Alert deliveryDashboard, email or SMS; app where required
RecipientsNamed people and groups, with escalation to further contacts
Gateway power lossRaises its own platform alert
Missed reportsA tag that misses its reporting interval is flagged in the dashboard
DashboardInterval use, running total, hourly to monthly use, overnight baseline, meters compared; configured to your requirement
RecordsEvery interval time-stamped and exportable
DataFull history; UK-hosted or on servers on your own site
PowerInternal battery, up to five years as standard; longer with additional cells
Radio433 MHz, one-way (transmit only)
Radio rangeSite-dependent; confirmed by site survey
EnvironmentIndoor or outdoor, enclosure specified to the location
MountingBeside the meter, in a cupboard, chamber or plant room
EnclosureStandard or built to the site; specified for chambers and pits
Not forBilling-grade metering; the meter remains the measure
ChargesNo per-alert, per-user or licence charges
ManufactureMade to order in the UK
CertificationCE marked

07

From requirement to live alerts

Requirement

Tell us which meters and what they serve. The meter's make and its pulse value are enough to start.

Configuration

Each tag is built to order for its meter, with the scaling factor, reporting interval and rules set.

Fitting

The tag is connected to the meter's pulse output and fixed beside it. The meter is not opened or altered.

Commissioning

The count is checked against the meter's register over a known volume or period, and alert routes are tested.

Ready to get started? Every deployment begins with a site survey.

Book a site survey

08

How it reports

Each interval's count goes over 433 MHz radio to a ZARC gateway and on to the dashboard, where scaling and rules are applied. The tag has a transmitter and no receiver, so nothing can reach the meter through it. The 433 MHz signal carries out of meter chambers and plant rooms where other radios struggle.

Questions we answer most.

What does the pulse counting tag do?

It counts the pulses from a meter or output you already have and reports use for each interval and as a running total.

What meters does it work with?

Water, electricity, gas and heat meters with a pulse output, and counters on machines.

Does it change the meter?

No. It reads the meter's pulse output. The meter and its accuracy are untouched.

Can it find a leak?

Yes. Use through the hours when nothing should be running raises an alert the same night.

Can it tell me a supply has stopped?

Yes. No count from a meter that should be turning raises a no-flow alert.

Does it show litres or kilowatt hours?

Yes. A factor set per meter turns pulses into litres, cubic metres, kilowatt hours or units.

Can it be used for billing?

It supports recharges with a record of use. It is not a billing-grade meter; the meter remains the measure.

Does it work in a meter chamber?

Yes. The 433 MHz signal carries out of chambers and pits, and the enclosure is specified for them.

Does it need power or a network?

No. It runs on an internal battery and reports by radio to a ZARC gateway.

How long does the battery last?

Up to five years as standard, and longer where additional cells are fitted.

Looking for something else?

We work with any sensor for any application.

Most sensing needs are met by a tag we already build, configured for your equipment. If yours needs a sensor or interface we don't list, we have the engineering to build it. Tell us what you need to measure, and we will tell you how we would do it.

Discuss your requirement

Discuss a monitoring
or alerting solution

Tell us what is happening on site, what you need to see, and the event you need to hear about. We will come back with the system that answers it.

Location

Venator House, Unit 9, 15-17 St Stephen's Road, Bournemouth

Dorset, BH2 6LA · VAT GB 409644484

Products contact

Contact the engineering team

Direct to the team that designs and builds the range. Tell us the equipment and the event that matters.

No mailing lists. No spam. We reply directly to your enquiry.