Water sub-meters
Use by building, floor or tenant, shown hour by hour, with a baseline that makes waste obvious.
The ZARC pulse counting tag counts the pulses from a meter or output you already have and reports how much has been used, interval by interval. It turns a water, electricity, gas or heat meter with a pulse output, or a counter on a machine, into live data. It alerts when there is use that should not be there, and when use that should be there has stopped. It runs on its own battery and the meter stays as it is.
01
The tag counts every pulse and reports the count for each interval and the running total, at the interval set for the site, down to every minute. A factor set per meter turns pulses into litres, cubic metres, kilowatt hours or units.
The pattern is the point. A meter read once a month gives a total. A count every few minutes shows when the use happened: through the night, at the weekend, during a shutdown.
Use when there should be none is the most valuable alert. Water running at three in the morning in a closed building is a leak or something left on. The tag reports it the same night, not at the next bill.
The reverse matters too. No pulses from a meter that should be turning means a supply has failed, a pump has stopped or a process is down.
The tag reads the meter's output and changes nothing about the meter. It is not a billing-grade meter; the meter remains the measure.
02
Most meters already have a pulse output that nobody is using. The uses below are the common ones.
Use by building, floor or tenant, shown hour by hour, with a baseline that makes waste obvious.
A steady count through the hours when nothing should be running. The alert arrives the first night.
Consumption by area, plant or tenant from meters with a pulse output.
Use by boiler house, building or heat network branch, from the meter's own pulse output.
Plant, taps and processes that carry on after hours, picked up as use against an empty building.
No count from a meter that should be turning: a failed supply, a stopped pump, a line that is down.
Items, cycles and strokes counted from an existing output, as a live production figure.
A record of who used what and when, to support a recharge. The meter remains the measure.
Strokes of a dosing pump or runs of a booster, so a pump that has stopped dosing is seen.
Where the aim is every meter on an estate read without visits, the metering solution covers the whole system.
03
The tag sits beside the meter or output it counts. Typical positions:
In the meter chamber or cupboard, on the pulse output.
In the distribution cupboard, on the meter's pulse terminals.
Beside the meter, connected to its pulse output by a competent person.
On the meters serving boilers, chillers and boosters.
At the counter or sensor output.
Below ground, where 433 MHz still reaches the gateway.
04
Every meter shows its use for each interval, its running total and a trend from the last hour to the last year. The dashboard works out use by hour, day, week and month, the overnight baseline, and sets meters and buildings side by side. Records export for energy reports, recharges and leak investigations.
Limits are set per meter: use when there should be none, no use when there should be some, and use above a limit for a period. When one is crossed the alert is raised in real time and goes by email or SMS, and through an app where required, to the people you name, with escalation to further contacts.
05
Pulse counting tags are fitted wherever a meter is read too rarely to be useful, including:
Water and energy by building and tenant.
Sub-meters, leaks and recharges.
Process meters and machine counters.
Gas, heat and water meters on networks.
Schools, offices and depots.
Water and energy across large sites.
06
| Parameter | Specification |
|---|---|
| Measurement | Pulses from a meter or output, counted continuously |
| Input | Volt-free pulse output or reed switch; fitted to suit the meter |
| Values reported | Count for each interval and running total |
| Scaling | Factor per meter: litres, cubic metres, kilowatt hours or units |
| Pulse rate | Specified to the meter |
| Meter changes | None; the meter and its accuracy are untouched |
| Reporting interval | Configurable, down to every minute |
| Use alerts | Flow or consumption when there should be none |
| No-flow alerts | No count when there should be some |
| Limit alerts | Use above a limit for a period you set |
| Time-of-day rules | Separate rules for occupied and empty hours |
| Alert delivery | Dashboard, email or SMS; app where required |
| Recipients | Named people and groups, with escalation to further contacts |
| Gateway power loss | Raises its own platform alert |
| Missed reports | A tag that misses its reporting interval is flagged in the dashboard |
| Dashboard | Interval use, running total, hourly to monthly use, overnight baseline, meters compared; configured to your requirement |
| Records | Every interval time-stamped and exportable |
| Data | Full history; UK-hosted or on servers on your own site |
| Power | Internal battery, up to five years as standard; longer with additional cells |
| Radio | 433 MHz, one-way (transmit only) |
| Radio range | Site-dependent; confirmed by site survey |
| Environment | Indoor or outdoor, enclosure specified to the location |
| Mounting | Beside the meter, in a cupboard, chamber or plant room |
| Enclosure | Standard or built to the site; specified for chambers and pits |
| Not for | Billing-grade metering; the meter remains the measure |
| Charges | No per-alert, per-user or licence charges |
| Manufacture | Made to order in the UK |
| Certification | CE marked |
07
Tell us which meters and what they serve. The meter's make and its pulse value are enough to start.
Each tag is built to order for its meter, with the scaling factor, reporting interval and rules set.
The tag is connected to the meter's pulse output and fixed beside it. The meter is not opened or altered.
The count is checked against the meter's register over a known volume or period, and alert routes are tested.
Ready to get started? Every deployment begins with a site survey.
Book a site survey08
Each interval's count goes over 433 MHz radio to a ZARC gateway and on to the dashboard, where scaling and rules are applied. The tag has a transmitter and no receiver, so nothing can reach the meter through it. The 433 MHz signal carries out of meter chambers and plant rooms where other radios struggle.
Water on the floor, where the meter shows it is being lost.
Supply pressure beside the flow.
Whether the plant behind the meter is running.
What is left in the tank the meter fills.
It counts the pulses from a meter or output you already have and reports use for each interval and as a running total.
Water, electricity, gas and heat meters with a pulse output, and counters on machines.
No. It reads the meter's pulse output. The meter and its accuracy are untouched.
Yes. Use through the hours when nothing should be running raises an alert the same night.
Yes. No count from a meter that should be turning raises a no-flow alert.
Yes. A factor set per meter turns pulses into litres, cubic metres, kilowatt hours or units.
It supports recharges with a record of use. It is not a billing-grade meter; the meter remains the measure.
Yes. The 433 MHz signal carries out of chambers and pits, and the enclosure is specified for them.
No. It runs on an internal battery and reports by radio to a ZARC gateway.
Up to five years as standard, and longer where additional cells are fitted.
Looking for something else?
Most sensing needs are met by a tag we already build, configured for your equipment. If yours needs a sensor or interface we don't list, we have the engineering to build it. Tell us what you need to measure, and we will tell you how we would do it.
Discuss your requirementTell us what is happening on site, what you need to see, and the event you need to hear about. We will come back with the system that answers it.
Direct contact
Location
Venator House, Unit 9, 15-17 St Stephen's Road, Bournemouth
Dorset, BH2 6LA · VAT GB 409644484
Products contact
Direct to the team that designs and builds the range. Tell us the equipment and the event that matters.