Air handling units
Supply fan and extract fan running or stopped, supply air temperature, and filter differential pressure on each unit.
We supply complete HVAC monitoring: battery-powered tags fitted to the plant you already have, with no rewiring and no connection to the building management system, a ZARC Gateway, and the dashboard that tells you the moment a fan stops, a filter blocks, a space drifts out of temperature or a unit trips, by SMS or email to the people you name, with a timestamped record of every reading. It works alongside a BMS, or in buildings that have none.

01
It answers the questions a facilities team asks about every HVAC unit: is it running, is it doing its job, and is anything about to stop it. A current clamp on the supply shows whether a fan, pump or compressor is running or stopped. Temperature probes on supply and return air or water show whether the unit is delivering. A differential pressure tag across a filter shows it loading up long before airflow fails.
Faults the plant already knows about are read straight from it. Most air handling units, chillers, heat pumps and condensing units have a volt-free fault or trip output, and a dry contact tag reports its state the moment it changes. Water from a blocked condensate drain, power lost to a unit and refrigerant escaping near the plant are reported as events of their own.
Every reading is kept, so the dashboard shows patterns as well as alarms: a unit that runs longer each week, a space that warms every afternoon, a filter that blocks faster than the last one. That history is the timestamped record for maintenance contracts, compliance checks and insurers.
The system is specified to the building: which units matter, which readings each one needs, the limits that count as a fault, and who is called in hours and out of hours.
02
Wherever a stopped fan, a warm room or a silent fault costs money or comfort, remote HVAC monitoring has a job. These are the systems we are asked about most, and the list is not exhaustive.
Supply fan and extract fan running or stopped, supply air temperature, and filter differential pressure on each unit.
Units on the roof that nobody sees until the floor below gets warm. Running state, discharge temperature and the unit's own fault output.
Chilled water flow and return temperature, compressor running, and the chiller's common fault output read without opening its controls.
Flow and return temperature, lockouts and run state, so a heating fault is known before the building cools.
Indoor unit temperature, outdoor unit running state and fault outputs, and refrigerant leak detection near the system.
Room and rack inlet temperature, the cooling unit's running state and its fault output, with alarms that reach the on-call team at night.
Running or stopped on every fan that keeps a space safe or comfortable, from car parks to toilets and kitchens.
A water tag in or beside the tray reports an overflow before it comes through the ceiling.
Circulating pumps running or stopped and system pressure falling, on heating and chilled water circuits.
A timestamped record of running hours, faults and response times for every unit, for contract reviews and compliance checks.
03
Each tag fits where its reading is, and runs on its own battery with no connection to the building network. Typical fittings:
A current clamp around one conductor in the panel or isolator, for running or stopped.
A differential pressure tag with its two ports either side of the filter.
Temperature probes in the airstream or strapped to the pipe surface.
A dry contact tag on the volt-free output the manufacturer already provides.
A water leak tag sitting where an overflow would collect.
Places other networks struggle to reach, with the gateway placed after a site survey.
04
Every HVAC unit appears on one live board showing whether it is running, the temperatures it is delivering and the state of its filters and fault outputs, grouped by building, floor or plant room. Each fault is recorded with when it started, when it cleared and how long it lasted. Trends run from one hour to one year, and the history exports for maintenance reviews, compliance checks and insurers. Real-time and historical telemetry is kept for as long as you need it, for compliance and audit, on a UK-hosted dashboard or on servers on your own site.
The dashboard raises the alarm in real time when a unit stops or trips, when a temperature crosses a limit, when a filter passes its differential pressure limit, when water appears in a tray and when refrigerant is detected near the plant. It sends each alarm by SMS or email to the people you name for that building, with escalation to further contacts and separate routes in and out of hours.
05
HVAC monitoring fits every sector that depends on heating, cooling and ventilation it cannot see, including:
One view of plant across every client building.
Offices, schools and mixed portfolios with plant on roofs and in basements.
Cooling that has to keep running, watched alongside the systems that run it.
Hospitals, clinics and care homes, where temperature and ventilation matter to patients.
Large estates with ageing plant and small teams.
Process cooling, extract and ventilation that keep a line running.
06
| Parameter | Specification |
|---|---|
| Systems | Air handling units, rooftop units, chillers, condensing units, heat pumps, boilers, split and VRF systems, fans and pumps |
| What it watches | Running state, supply and return temperatures, filter loading, fault and trip outputs, condensate, refrigerant and power |
| BMS | Works alongside a building management system, or where there is none |
| Fitting | No rewiring and no opening of the plant's controls |
| Alarms | Raised by the dashboard in real time and sent by SMS or email, with escalation |
| Parameter | Specification |
|---|---|
| Dashboard | Real-time and historical telemetry for compliance and audit |
| Data | Kept for as long as you need it; UK-hosted or on servers on your own site |
| Power | Battery-powered tags; only the gateway needs a power supply |
| Connectivity | 433 MHz to a ZARC Gateway on 4G, Wi-Fi or Ethernet |
| Manufacture | Designed and manufactured in the UK; UKCA marked |
07
You tell us which units matter, what a failure costs in each building, and who is called in hours and out of hours.
We choose the readings for each unit, set the temperature, pressure and running limits, and build the alarm routes.
Clamps, probes and tags are fitted to the plant without rewiring or opening its controls. Where site rules require a qualified electrician or an F-gas engineer, we work alongside yours.
We check each reading against the unit's own display, trip each fault output where it is safe to do so, and send a test alarm to every recipient before handover.
Ready to get started? Every deployment starts with a conversation with one of our engineers.
Talk to an engineer08
Each tag sends over 433 MHz radio to a ZARC Gateway on site, which passes the reading to the dashboard over 4G, Wi-Fi or Ethernet. The dashboard checks every reading against its limits and raises the alarm. The radio reaches into plant rooms, risers and roofs that other networks struggle to reach. The tags only transmit; with no receiver on board, nothing can alter their settings or reach them over the air.
Each point is two parts: the sensor or input that suits the job, and the ZARC tag we build it into, which carries the sensor's readings over our own 433 MHz radio to the ZARC Gateway and the dashboard.
Running or stopped for fans, pumps and compressors.
Filter loading across an air handling unit.
Supply, return, room and pipe temperatures.
The unit's own fault, trip and lockout outputs.
An HVAC monitoring system tells a facilities team when heating, ventilation or air conditioning plant stops, trips or stops doing its job. Battery-powered tags read running state, temperatures, filter pressure and fault outputs, and the dashboard raises the alarm by SMS or email.
Yes. Air conditioning monitoring needs nothing else on the system: a current clamp shows whether each unit is running, probes read the air it delivers and the room it serves, and a dry contact tag reads the unit's fault output. The dashboard raises the alarm when a unit stops, trips or the room drifts out of temperature.
Yes. Each building has its own ZARC Gateway, and every unit on every site reports to the same dashboard, grouped by building, floor or plant room, with alarm routes set per building.
No. It runs independently of the BMS and works alongside one, or in buildings that have none. Many teams use it to cover plant the BMS does not reach, or to get alarms to people who do not sit in front of the BMS.
No. Current clamps go around one conductor, probes fit in the duct or on the pipe, and fault outputs are read from the volt-free terminals the manufacturer provides. Where site rules require a qualified electrician, we work alongside yours.
A differential pressure tag reads the pressure drop across the filter bank. As the filter loads, the drop rises, and the dashboard raises the alarm at the limit you set, before airflow falls far enough to affect the space.
Yes. A refrigerant gas sensor, specified to the refrigerant in the system, is placed near the plant and connected to a tag. The dashboard raises the alarm when refrigerant is detected. It supports the leak-check records F-gas rules expect; it does not replace the statutory checks or a certified leak detection system where one is required.
Events such as a unit stopping or a fault output changing typically reach the dashboard within a second. Readings such as temperature arrive at an interval you set, down to every minute, and the alarm is raised as soon as one crosses a limit.
Whoever you name for each building: facilities managers, engineers, the on-call contractor or key-holders. The dashboard sends alarms by SMS or email, with separate routes in and out of hours and escalation to further contacts.
Yes. Every reading, alarm, start and clear time is kept as a timestamped record, held for as long as you need it, and exports for maintenance contract reviews, compliance checks and insurers.
Yes. The 433 MHz radio is chosen for its reach through walls, floors and metal enclosures. Range is site-dependent and is confirmed by a site survey before the gateway is placed.
Each tag is battery-powered, up to five years as standard and longer with additional cells. Only the gateway needs a power supply, and battery backup is available for it.
Yes. Once a building has its gateway, further tags of any kind join the same dashboard, from water leaks to door state and power failure.
Looking for something else?
Most sensing needs are met by a tag we already build, configured for your equipment. If yours needs a sensor or interface we don't list, we have the engineering to build it. Tell us what you need to measure, and we will tell you how we would do it.
Discuss your requirementTell us what is happening on site, what you need to see, and the event you need to hear about. We will come back with the system that answers it.